Bonding for Other Systems. Enter the intersystem bonding termination Section 250. Code, thereby affecting all new installations and existing installations where alterations are made.
This device seems like a neat way to do it. An intersystem bonding termination for connecting intersystem bonding conductors required for other systems shall be provided external to enclosures at the service equipment or metering equipment enclosure and at the disconnecting means for any additional buildings or structures. Copper Termination Ground Bar from Blackburn is ideal for mounting on walls, water pipes or conduits to offer versatility.
Fill Your Cart With Color today! Used in residential and commercial applications to ground up to four (4) systems to a single location. Lay-in style connection and good for up to four auxiliary ground wires. Available in die-cast zinc or copper alloy. Approved for use with solid or stranded copper conductors.
The bonding bar shall be connected to the grounding electrode conductor with a minimum AWG copper conductor. Long gone are the days of conductor clutter. In addition to the abovementioned requirements, the intersystem bonding termination is required to be maintained accessible for connection and inspection. Only time will tell if the communications industry will use or disregard the intersystem bonding termination , as so often was the case with the old method of using a No.
For structures supplied by a feeder, you must provide an external intersystem bonding terminal at the metering equipment enclosure and disconnecting means. Consist of a set of terminals with the capacity for connecting at least three intersystem bonding conductors. You must register before you can post: click the register link above to proceed. The intersystem bonding termination must: The intersystem bonding termination shall comply with six specific requirements. Learn vocabulary, terms, and more with flashcards, games, and other study tools.
Be accessible for connection and inspection. IBT3A IBT3C IBT3AB IBT3CB Description FIG. Wound a bus bar connected to the exterior of a meter socket (for bonding intersystem grounding conductors) with self tapped screws and no bonding wire be a code violation? HARRISBURG, NC – Galvan Industries is now offering contractors cost-efficient die-cast zinc intersystem bonding bridge connectors.
The IBTB is mounted adjacent to the meter base or service entrance equipment and is a convenient way to interconnect and. A bonding bar near the grounding electrode conductor. The conduit poking out of the ground is the electric utility company’s underground service feed for the electric meter.
An intersystem bonding termination (IBT) for connecting intersystem bonding conductors shall be provided external to enclosures at the service equipment or metering equipment enclosure and at the disconnecting means for any additional buildings or structures. It is also used to bond grounding conductors from CATV or satellite dish conductors, security systems, landscape lighting controls and lightning protection systems. If the building or structure served has no intersystem bonding termination or grounding means, as described in 800. All can be used with copper or aluminum, solid or stranded.
Multi-Connection Secondary Termination Fasteners Bolts. Provides reliable intersystem bonding between power and communication grounding systems. Comes with texture paintable, white cover. Cover is UV rated plastic for long outdoor life. Body made of die-cast zinc.
Username (Email Address) Password. Remember me Forgot Password? A device that provides a means for connecting intersystem bonding conductors for communication systems and other systems such as metallic gas piping systems to the grounding electrode system. Eritec-Caddy Catalog Number IBTB Manufacturer Erico, Inc. It has impact-resistant polymer construction.
Printing functionality is restricted without a premiumACCESS subscription. International Residential Code. In Buildings of Structures with Grounding Means. This is typically a terminal affixed to the outside of the service equipment enclosure, or a terminal on the outside of the house that is connected to the service equipment. Inch Depth, Impact Resistant Polymeric Base and Housing, Includes Mounting Hardware, Application Residential and Small Commercial, UL (Canada and US) Liste Applicable Standard NEC 250.
Two-piece clamp mounts vertically on th eside or horizontally across the top of a meter box without interfering with cover removal. It shall be provided external to enclosures at the service equipment or metering equipment enclosure, and at the disconnecting means for any additional buildings or structures. One Connector Does It All, House Mount Or.
This must be located near the electric meter. The bonding conductor or grounding electrode conductor must terminate in accordance with (1), (2), or (3). The meter socket must not be drilled or damaged during installation of an intersystem bonding termination device required by Article 250.