Tuesday, August 14, 2018

Intersystem bonding terminal

Bonding for Other Systems. Enter the intersystem bonding termination Section 250. Code, thereby affecting all new installations and existing installations where alterations are made. IBT3A IBT3C IBT3AB IBT3CB Description FIG.


Per article 10 the intersystem bonding terminal is only for communication systems. What harm would there be if the Gastite bond wire was landed to it? It is very convenient for doing so given the usual close proximity of the gas meter and bonding terminal. You can’t have “separate grounds” between communications systems and your service.


For structures supplied by a feeder, do this at the metering equipment enclosure and disconnecting means (Fig. 4). A device that provides a means for connecting intersystem bonding conductors for communications systems to the grounding electrode system. All can be used with copper or aluminum, solid or stranded.


While we called it intersystem bonding , we still needed some guidelines to follow. A set of terminals securely mounted to the meter enclosure and electrically connected to the meter enclosure. The terminals shall be listed as grounding and bonding equipment. Intersystem bonding termination for residential and small commercial facilities.


If done correctly, properly terminating the bonding terminals in a communications system in preventing a situation where a difference in voltage potential exists between the premises electrical system and the communications system. BR and CH Terminal Plug-On Neutral Ground Bar Quick easy and clean describe the new plug-on Quick easy and clean describe the new plug-on neutral design attributes offered by Eaton. Time saving features offer a quick installation equating to less time on the job.


Intersystem bonding terminal

Fill Your Cart With Color Today! The intersystem bonding termination shall comply with the following: Be accessible for connection and inspection. Consist of a set of terminals with the capacity for connection of not less than three intersystem bonding conductors. AWG An external terminal bar on the service enclosure is required for connecting GECs of other systems. The bond to the service equipment must be at least a 6AWG conductor.


He wanted me to install an IDEAL intersystem bonding terminal. Hopefully you can picture this. Provides reliable intersystem bonding between power and communication grounding systems.


Intersystem bonding terminal

Cover is UV rated plastic for long outdoor life. One Connector Does It All, House Mount Or Meter Socket Mount, Incorporates Proven BURNDY SERVIT POST. A) The purpose of grounding and bonding communications systems, as defined in NEC Article 90. NEC Articles 2and 8describe the specific protection requirements for each type of facility. A full Grounding line covering all applications, featuring heavy duty, direct burial clamps, and range taking rod clamps.


Can I run one ground wire from Outdoor antenna to bond to the IBT intersystem bonding terminal ? NEC and Antenna mast and coax Installing an antenna mast on the roof. The IBT ( intersystem bonding terminal ) is on the other side of the house near the service. NEC spat out the intersystem bonding block. Both ends of the raceway must be bonded to the contained conductor or to the same terminal or electrode to which the bonding conductor grounding electrode conductor is connected.


INTERSYSTEM BONDING – GBK, MBK;. Hello looking to bond the intersystem bonding terminal to the service ground but it is inside the box and goes down behind the stucco instead of outside. Standard locknuts or bushings shall not be considered a means of bonding the service raceway to the enclosure. That version of the NEC was the first to require an intersystem bonding terminal for low-voltage communication equipment such as television cables. An intersystem bonding terminal shall be provided at the service disconnect or metering equipment location external to the enclosure.


Only time will tell if the communications industry will use or disregard the intersystem bonding termination, as so often was the case with the old method of using a No. In this case the grounding terminal is bonded to the neutral terminal using the bonding screw (green arrow) provided by the manufacturer. The yellow arrow shows the bonding bar used to accomplish this. You should also read NFPA 7on lightning protection. Some manufacturers of CSST offer a product with a black outer “arc-resistant” jacket, which is designed to show that it’s an arc-resistant product.


This is typically a terminal affixed to the outside of the service equipment enclosure, or a terminal on the outside of the house that is connected to the service equipment. It is also used to bond grounding conductors from CATV or satellite dish conductors, security systems, landscape lighting controls and lightning protection systems. The NID protects the cable and routes is to the inside of the building and to the secondary protection system.


The NID also has a grounding structure including the grounding conductors the inersystem bonding terminal and the buss bar The NEC also has other items that identify amplifying information and change since the last printing. Also there is an intersystem bonding terminal right below the panel, why not just wire the ground wire to the lug right next to the stranded aluminum ground wire and then connect the bonding wire for the gas meter to the intersystem bonding terminal ?