Intersystem bonding

Bonding for Other Systems. It has a compact design and includes a U. The bonding bar shall be connected to the grounding electrode conductor with a minimum AWG copper conductor. Long gone are the days of conductor clutter. In addition to the abovementioned requirements, the intersystem bonding termination is required to be maintained accessible for connection and inspection. All can be used with copper or aluminum, solid or stranded.


An intersystem bonding termination for connecting intersystem bonding conductors required for other systems shall be provided external to enclosures at the service equipment or metering equipment enclosure and at the disconnecting means for any additional buildings or structures. Intersystem bonding termination for residential and small commercial facilities. For structures supplied by a feeder, do this at the metering equipment enclosure and disconnecting means ( Fig. ). Lay-In feature eliminates disassembling ground to rod connection. Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death.


DOES NOT guarantee the accuracy or completeness of any information contained on this site. AWG bonding conductors and one Class I copper lightning conductor. A bonding bar near the grounding electrode conductor.


HARRISBURG, NC – Galvan Industries is now offering contractors cost-efficient die-cast zinc intersystem bonding bridge connectors. The intersystem bonding termination must: The intersystem bonding termination shall comply with six specific requirements. Be accessible for connection and inspection.


Consist of a set of terminals with the capacity for connection of not less than three intersystem bonding conductors. CSST bonding requirements (another update). One place that isn’t a proper bonding location is the intersystem bonding terminal, which can be found at the. Fill Your Cart With Color today!


Intersystem bonding

Used in residential and commercial applications to ground up to four (4) systems to a single location. Used inside or outside of an enclosure or panel board in conjunction with a Rigid Metallic Conduit with 3-equipment bonding terminations. Removable plastic cover is included to provide long lasting outdoor life. In Stock Product Information. It is also used to bond grounding conductors from CATV or satellite dish conductors, security systems, landscape lighting controls and lightning protection systems.


Our POCO allows this bar to be connected to the socket. Would this be considered electrically connected as required by 250. IBT3A IBT3C IBT3AB IBT3CB Description FIG. The conduit poking out of the ground is the electric utility company’s underground service feed for the electric meter. AWG An external terminal bar on the service enclosure is required for connecting GECs of other systems.


Only time will tell if the communications industry will use or disregard the intersystem bonding termination, as so often was the case with the old method of using a No. Show latest replies on top. I feel that the inter system bonding conection is now part of the code, so when. GBINTERSYSTEM BONDING TERM Item No.


Fabricated from tin plated zinc for optimal conductivity with stainless steel hardware and a weather resistant polycarbonate cover. An intersystem bonding termination (IBT) for connecting intersystem bonding conductors shall be provided external to enclosures at the service equipment or metering equipment enclosure and at the disconnecting means for any additional buildings or structures. Fabricated from corrosion resistant bronze with stainless steel hardware, includes polycarbonate cover that repels damaging elements.


Intersystem bonding

Provides reliable intersystem bonding between power and communication grounding systems. Comes with texture paintable, white cover. Cover is UV rated plastic for long outdoor life. Picture shows how intersystem bonding is accomplished. Weve gathered the most popular styles with strategies for how you can place them where to put them.


This connector is suitable for both indoor and outdoor use. Canadian Electrical Code, Part I. Then install the bonding wire from the meter socket, through the pvc, through the bonding block, down to the ground rods. Connector is cULus listed. The IBTB is mounted adjacent to the meter base or service entrance equipment and is a. With Ideal Covers Seller assumes all responsibility for this listing. Includes snap in place plastic cover.


The bonding conductor or grounding electrode conductor must terminate in accordance with (1), (2), or (3).